Table 21 2023 Notional Specification for reference to proposed scenarios
Element / System Unit Reference EPC Data (Mean)

2023 Notional

ASHP

2023 Notional

DE

2023 Notional

DHN

External Wall U-value [W/m2.K] 0.20 0.15 0.15 0.15
Floor U-value [W/m2.K] 0.15 0.12 0.12 0.12
Roof U-value [W/m2.K] 0.12 0.09 0.09 0.09
Window U-value [W/m2.K] 1.40 1.2 1.2 1.2
Air Tightness [m3/h/m2@ 50pa] 4.60 5 5 5
Heating efficiency [%] 93% 250% 93% Same as Actual
Water efficiency [%] 87% 250% 87% Same as Actual
Standing Loss [kWh/d] -

DE: 1.80 (230 litres)

MT / ET: 1.70 (210 litres)

SF: 1.39 (150 litres)

LF: 1.60 (190 litres)

DE: 1.70 (210 litres)

MT /ET: 1.55 (180 litres)

SF: 1.39 (150 litres)

LF: 1.22 (120 litres)

N/A
SFP (SAP) [W/l/s] - N/A N/A N/A
HR [%] - N/A N/A N/A
Lighting efficacy [lm/W] - 80 80 80
PV [Wp/m2] 20.8 0

DE: 31.04

MT/ET: 30.78

SF: 15.38

LF: 15.46

DE: 31.04

MT/ET: 30.78

SF: 15.38

LF: 15.46

PV area relative to ground floor (per SAP 10.2) [%] - 0 40 40
PV panel efficiency [m2/kWp] - N/A 6.5 6.5
WWHR [%] - N/A N/A N/A
Table 22 ‘Business as Usual’ Specification
Element / System Unit Reference EPC Data (Mean)

BAU

ASHP

BAU

DE

BAU

DHN

External Wall U-value [W/m2.K] 0.20 0.17 0.17 0.17
Floor U-value [W/m2.K] 0.15 0.15 0.15 0.15
Roof U-value [W/m2.K] 0.12 0.11 0.11 0.11
Window U-value [W/m2.K] 1.40 1.4 1.4 1.4
Air Tightness [m3/h/m2@50pa] 4.60 4.6 4.6 4.6
Heating efficiency [%] 93%

DE: 323%*

MT / ET: 345%*

SF: 291%*

LF: 336%*

100%

93% (10% gas boiler)

250% (90% electric HP)

Water efficiency [%] 87%

DE: 223%*

MT / ET: 227%*

SF: 218%*

LF: 218%*

100% As above
Standing Loss [kWh/d] -

From integrated HIU

DE: 1.80 (230 litres)

MT / ET: 1.50 (210 litres)

SF: 1.25 (150 litres)

LF: 1.45 (190 litres)

ErP B

DE: 1.50 (210 litres)

MT /ET: 1.42 (180 litres)

SF: 1.25 (150 litres)

LF: 1.34 (120 litres)

1.44 (Indirect HIUSAP Default)
SFP (SAP) [W/l/s] - 0.15 0.15 0.15
HR [%] - N/A N/A N/A
Lighting efficacy [lm/W] - 80 80 80
PV [Wp/m2] 20.8 0

DE: 31.04

MT/ET: 30.78

SF: 15.38

LF: 15.46

DE: 23.28

MT/ET: 23.09

SF: 11.54

LF: 11.59

PV area relative to ground floor (per SAP 10.2) [%] - 0 40 30
PV panel efficiency [m2/kWp] - N/A 6.5 6.5
WWHR [%] - N/A N/A N/A
Table 23 ‘Good Practice’ Specification
Element / System Unit Reference EPC Data (Mean)

Good

ASHP

Good

DE

Good

DHN

External Wall U-value [W/m2.K] 0.20 0.15 0.15 0.15
Floor U-value [W/m2.K] 0.15 0.11 0.11 0.11
Roof U-value [W/m2.K] 0.12 0.11 0.11 0.11
Window U-value [W/m2.K] 1.40 1.2 1.2 1.2
Air Tightness [m3/h/m2@50pa] 4.60 3 3 3
Heating efficiency [%] 93%

DE: 323%*

MT / ET: 345%*

SF: 291%*

LF: 336%*

100%

93% (10% gas boiler)

250% (90% electric HP)

Water efficiency [%] 87%

DE: 223%*

MT / ET: 227%*

SF: 218%*

LF: 218%*

100% As above
Standing Loss [kWh/d] -

From integrated HWC

DE: 1.80 (230 litres)

MT / ET: 1.50 (210 litres)

SF: 1.25 (150 litres)

LF: 1.45 (190 litres)

ErP A

DE: 1.07 (210 litres)

MT /ET: 1.02 (180 litres)

SF: 0.90 (150 litres)

LF: 0.96 (120 litres)

1.00 (Indirect HIUCIBSE CP1)
SFP (SAP) [W/l/s] - 0.15 0.15 0.15
HR [%] - N/A N/A N/A
Lighting efficacy [lm/W] - 100 100 100
PV [Wp/m2] 20.8 0

DE: 44.83

MT/ET: 44.46

SF: 22.22

LF: 22.33

DE: 33.62

MT/ET: 33.35

SF: 16.67

LF: 16.67

PV area relative to ground floor (per SAP 10.2) [%] - 0 40 30
PV panel efficiency [m2/kWp] - N/A 4.5 4.5
WWHR [%] - N/A 58 58
Table 24 ‘Best Practice’ Specification
Element / System Unit Reference EPC Data (Mean)

Best

ASHP

Best

DE

Best

DHN

External Wall U-value [W/m2.K] 0.20 0.12 0.12 0.12
Floor U-value [W/m2.K] 0.15 0.1 0.1 0.1
Roof U-value [W/m2.K] 0.12 0.1 0.1 0.1
Window U-value [W/m2.K] 1.40 0.8 0.8 0.8
Air Tightness [m3/h/m2@50pa] 4.60 1.5 1.5 1.5
Heating efficiency [%] 93%

DE: 323%*

MT / ET: 345%*

SF: 291%*

LF: 336%*

100%

93% (10% gas boiler)

250% (90% electric HP)

Water efficiency [%] 87%

DE: 223%*

MT / ET: 227%*

SF: 218%*

LF: 218%*

100% As above
Standing Loss [kWh/d] -

From integrated HWC

DE: 1.80 (230 litres)

MT / ET: 1.50 (210 litres)

SF: 1.25 (150 litres)

LF: 1.45 (190 litres)

ErP A

DE: 1.07 (210 litres)

MT /ET: 1.02 (180 litres)

SF: 0.90 (150 litres)

LF: 0.96 (120 litres)

1.00 (Indirect HIUCIBSE CP1)
SFP (SAP) [W/l/s] -

DE: 1.19

MT/ET: 0.95

SF: 0.61

LF: 0.74

DE: 1.19

MT/ET: 0.95

SF: 0.61

LF: 0.74

DE: 1.19

MT/ET: 0.95

SF: 0.61

LF: 0.74

HR [%] - 90 90 90
Lighting efficacy [lm/W] - 120 120 120
PV [Wp/m2] 20.8

DE: 22.41

MT/ET: 22.23

SF: 11.11

LF: 11.16

DE: 44.83

MT/ET: 44.46

SF: 22.22

LF: 22.33

DE: 33.62

MT/ET: 33.35

SF: 16.67

LF: 16.67

PV area relative to ground floor (per SAP 10.2) [%] - 20 40 30
PV panel efficiency [m2/kWp] - 4.5 4.5 4.5
WWHR [%] - N/A 58 58