Technical analysis to consider the implications of modelling method, dwelling specification and heating technology up key regulated metrics and costs to both the developer and occupier, to represent the emerging building stock in Scotland.


Appendix A SAP 10.2 Compliance Margin

Table 20 Results from SAP 10.2 modelling to validate compliance margin achieved by BAU DDER with respect to the Notional
Archetype Heating Technology Notional DDER (kWh/yr) BAU DDER (kWh/yr) BAU Pass Margin (%)
Detached ASHP 25.94 24.48 6%
Detached DE 52.18 46.66 11%
Detached DHN 55.46 53.46 4%
End Terrace ASHP 23.41 22.68 3%
End Terrace DE 45.68 39.89 13%
End Terrace DHN 49.98 45.46 9%
Mid Terrace ASHP 21.85 20.11 8%
Mid Terrace DE 40.74 35.35 13%
Mid Terrace DHN 45.09 40.42 10%
Block of Flats ASHP 24.06 23.41 3%
Block of Flats DE 50.48 46.25 8%
Block of Flats DHN 55.36 39.93 28%