Appendix A SAP 10.2 Compliance Margin
| Archetype | Heating Technology | Notional DDER (kWh/yr) | BAU DDER (kWh/yr) | BAU Pass Margin (%) |
|---|---|---|---|---|
| Detached | ASHP | 25.94 | 24.48 | 6% |
| Detached | DE | 52.18 | 46.66 | 11% |
| Detached | DHN | 55.46 | 53.46 | 4% |
| End Terrace | ASHP | 23.41 | 22.68 | 3% |
| End Terrace | DE | 45.68 | 39.89 | 13% |
| End Terrace | DHN | 49.98 | 45.46 | 9% |
| Mid Terrace | ASHP | 21.85 | 20.11 | 8% |
| Mid Terrace | DE | 40.74 | 35.35 | 13% |
| Mid Terrace | DHN | 45.09 | 40.42 | 10% |
| Block of Flats | ASHP | 24.06 | 23.41 | 3% |
| Block of Flats | DE | 50.48 | 46.25 | 8% |
| Block of Flats | DHN | 55.36 | 39.93 | 28% |