Householder permitted development rights: guidance
This guidance has since been superseded by Householder permitted development rights: guidance (Updated 2021)
4. Making changes to a dwellinghouse
4.1
The relevant
permitted development rights
for the main types of householder developments are
explained within this section.
4.2
Permitted development rights
for the different types of development are described
within a "class". Most classes are subject to limitation and
restrictions. The main householder classes are grouped into the
following categories:
- Enlarging a dwellinghouse
- Improvements, additions or other alterations to a dwellinghouse that are not an enlargement
- Other developments within the curtilage of a dwellinghouse
4.3
Permitted development rights for flats are detailed in
Section 5
.
4.4
Section 6
details permitted development rights for microgeneration
and
Section 7
details the regulations for
CCTV.
4.5
All the limitations within a class must be complied with. In
addition, permitted development rights are removed if the proposed
development is to create or materially widen a means of access to a
trunk road or classified road or creates an obstruction that is
likely to causes a hazard for people using the road.
Introduction to Enlarging a Dwellinghouse
4.6
It is important to understand the definition of
enlargement
. Enlargement is defined as any development that increases
the internal volume of the
original dwellinghouse
and includes a canopy or roof, with or without walls,
which is attached to the
dwellinghouse
, but does not include a
balcony
. Therefore, a car-port is an
enlargement
but a
balcony
is not.
4.7
There are many types of
enlargements
. The following 4 classes cover the most common types of
enlargements for
dwellinghouses
.
Single storey ground floor extension
Class 1A - Any enlargement of a dwellinghouse by way of a single storey ground floor extension, including any alteration to the roof required for the purpose of the enlargement.
This class covers the typical single storey extension to the rear of the property. Typical developments include conservatories, car-ports as well as other canopies or roofs, with or without walls.
Ground floor extension of more than one storey
Class 1B - Any enlargement of a dwellinghouse by way of a ground floor extension consisting of more than one storey including any alteration to the roof required for the purpose of the enlargement.
This class covers the typical 2 storey extension. The limitations set a minimum distance of 10 metres between the extension and any boundary, since many 1½ storey and 2 storey extension are more likely to have a greater impact than a single storey extension. It is recognised that the majority of extensions will not be able to meet this criteria, therefore an application for planning permission would be required in most instances.
Class 1C - The erection, construction or alteration of any porch outside any external door of a dwellinghouse.
This class allows for the construction of a small porch on any external door.
Class 1D - Any enlargement of a dwellinghouse by way of an addition or alteration to its roof.
This class allows for the construction of a typical rear facing dormer.
4.8
These permitted development rights do NOT apply to
flats.
4.9
If the proposed development falls into any of the above
classes and is in a
conservation area
then an application to the
planning
authority
is required.
4.10
A
listed building consent
is required if the proposed development affects the
character or setting of a
listed building
. A building warrant from the local authority is also
often required, as explained in
Section 2
.
Single storey ground floor extensions
SUMMARY
4.11
This is the most popular type of development. Permitted
development rights allow the
enlargement
of a
dwellinghouse
by a single storey ground floor extension. The permitted
development rights allow any alteration to the roof required for
the purpose of the
enlargement
. In summary, the effect of the limitations is that:
- extensions are generally located to the rear
- if the extension is on, or within 1 metre of the boundary, it cannot project, from the rear wall of the existing dwellinghouse, by more than 3 metres in the case of terraced house, or 4 metres in all other cases
- the height of the eaves is a maximum of 3 metres
- the height of the extension is not higher than 4 metres
- the footprint of the extension is no larger than the original dwellinghouse or covering more than half the curtilage
4.12
There are no permitted development rights for single storey
ground floor extensions in
conservation areas
or for flats. Listed building consent will normally be
required if your building is Listed.
4.13
A building warrant from the local authority will likely be
required for this type of extension, as explained in
Section 2
.
TECHNICAL EXPLANATION
4.14
If the extension exceeds any of the following limits then an
application for planning permission is required.
4.15
Roof alterations relating to the extension are also
permitted. Other roof alterations should be carried out using the
other relevant permitted development classes.
4.16
The extension
cannot be forward of a wall forming part of the
principal elevation or side elevation if that elevation is fronting
a road. The identification of the
principal elevation
and side elevations are discussed in paragraphs 3.2 -
3.6, whilst
fronting a road
is discussed at 3.7 - 3.10. This is illustrated in figure
13.
Figure 13: The shaded areas of the curtilage indicate where a single storey extension is permitted as long as the other limitations are met.
4.17
If any part of the extension is within 1 metre of the
boundary of the curtilage, it can only project from the line of the
rear elevation nearest to the boundary by 3 metres if a
terraced house
or 4 metres in any other case.
4.18
This restriction does not apply to a side extension that
does not project beyond the line of the rear elevation. For example
if a side extension, does extend beyond the line of the rear wall
and is within 1 metre of the rear wall and is within 1 metre of the
boundary, then it cannot project from the rear wall nearest the
boundary by more than 3 metres if a terraced house or 4 metres in
any another case.
4.19
The overall height of an extension can have a significant
impact on neighbours. The
eaves
of the extension
cannot be higher than 3 metres. The overall height
of the extension
cannot exceed 4 metres.
4.20
When measuring the height of the extension on sloping, or
uneven ground, the height should be measured from the lowest point
immediately adjacent to the extension.
4.21
The area covered by all extensions, including any existing
and the proposed extension, cannot be greater than the footprint of
the original dwellinghouse. This is to ensure that the extension
(including previous extensions) is in proportion to the original
dwellinghouse.
4.22
The proposed extension (including previous extensions) and
existing developments cannot exceed half of the of the rear (or
front if appropriate) curtilage of the original dwellinghouse. This
is explained further in paragraphs 3.12 - 3.13.
4.23
There are no Class 1A permitted development rights in a
conservation area
or for
flats
. A listed building consent is required if the proposed
extension affects the character or setting of a listed
building.
4.24
Planning authorities will be able to confirm whether a
property is located within a conservation area. Information on
listed buildings is available from
http://www.historic-
scotland.gov.uk/historicandlistedbuildings or
www.environment.scotland.gov.uk.
LEGISLATION
Class 1A.-
(1) Any enlargement of a dwellinghouse by way of a single storey ground floor extension, including any alteration to the roof required for the purpose of the enlargement.
(2) Development is not permitted by this class if-
(a) any part of the development would be forward of a wall forming part of the principal elevation or side elevation where that elevation fronts a road;
(b) any part of the development would be within 1 metre of the boundary of the curtilage of the dwellinghouse and it would extend beyond the line of the wall forming part of the rear elevation that is nearest that boundary by more than-
(i) 3 metres in the case of a terrace house; or
(ii) 4 metres in any other case;
(c) the height of the eaves of the development would exceed 3 metres;
(d) any part of the development would exceed 4 metres in height;
(e) as a result of the development the area of ground covered by the resulting dwellinghouse would be more than twice the area of ground covered by the original dwellinghouse;
(f) as a result of the development the area of ground covered by development within the front or rear curtilage of the dwellinghouse (excluding the original dwellinghouse and any hard surface or deck) would exceed 50% of the area of the front or rear curtilage respectively (excluding the ground area of the original dwellinghouse and any hard surface or deck); or
(g) it would be within a conservation area.
Ground floor extension of more than a one storey
SUMMARY
4.25
Permitted development rights allow the
enlargement
of a
dwellinghouse
by the way of a ground floor extension consisting of more
than one storey. The permitted development rights also allow any
alteration to the roof required for the purpose of the enlargement.
In summary, the effect of the limitations is that:
- extensions are generally located to the rear
- the distance between the extension and any boundary is a minimum of 10 metres
- the height of the extension is not higher than the existing dwellinghouse
- the footprint of the extension is not larger than the original dwellinghouse or covering more than half the curtilage
4.26
Many 1½ storey and 2 storey extensions are more
likely to have a greater impact than a single storey extension. It
is recognised that the majority of 1½ storey and 2 storey
extensions will require an application for planning permission.
4.27
There are no permitted development rights in
conservation areas
or for flats. Listed building consent will normally be
required if your building is Listed.
4.28
A building warrant from the local authority will be required
for this type of extension, as explained in
Section 2
.
TECHNICAL EXPLANATION
4.29
If the extension exceeds any of the following limits then an
application for
planning permission
is required.
4.30
The extension
cannot be forward of a wall forming part of the
principal elevation or side elevation if that elevation is fronting
a road. The identification of the principal elevation and side
elevations are discussed in paragraphs 3.2 - 3.6, whilst
fronting a road
is discussed at 3.7 - 3.10. This is illustrated in figure
14.
Figure 14: The shaded areas of the curtilage indicate where an extension of more than a single storey is permitted as long as the other limitations are met.
4.31
1½ storey or 2 storey extensions are more
likely to have a visual impact, potentially causing overshadowing
or overlooking. No part of the extension can therefore be within 10
metres of any boundary of the
curtilage
.
4.32
The overall height of the extension
cannot be higher than the existing roof. This
would be the ridge of the roof. Roof alterations relating to the
extension are also permitted. Other roof alterations should be
carried out using the other relevant classes.
4.33
The area covered by all extensions, including any existing
and the proposed extension, cannot be greater than the footprint of
the original dwellinghouse. This is to ensure that the extension
(including previous extensions) is in proportion to the original
dwellinghouse.
4.34
The proposed extension (including previous extensions) and
existing developments cannot exceed half of the rear (or front if
appropriate) curtilage of the
original dwellinghouse
. This is explained further in paragraphs 3.11 - 3.13.
4.35
There are no Class 1B permitted development rights in a
conservation area
or for flats. A listed building consent is required if
the proposed extension affects the character or setting of a listed
building.
4.36
Planning authorities will be able to confirm whether a
property is located within a conservation area. Information on
listed buildings is available from
http://www.historic-scotland.gov.uk/historicandlistedbuildings
or
www.environment.scotland.gov.uk.
LEGISLATION
Class 1B.-
(1) Any enlargement of a dwellinghouse by way of a ground floor extension consisting of more than one storey, including any alteration to the roof required for the purpose of the enlargement.
(2) Development is not permitted by this class if-
(a) any part of the development would be forward of a wall forming part of the principal elevation or side elevation where that elevation fronts a road;
(b) any part of the development would be within 10 metres of the boundary of the curtilage of the dwellinghouse;
(c) as a result of the development the height of the dwellinghouse would exceed the height of the existing dwellinghouse, when measured at the highest part of the roof and excluding any chimney;
(d) as a result of the development the area of ground covered by the resulting dwellinghouse would be more than twice the area of ground covered by the original dwellinghouse;
(e) as a result of the development the area of ground covered by development within the front or rear curtilage of the dwellinghouse (excluding the original dwellinghouse and any hard surface or deck) would exceed 50% of the area of the front or rear curtilage respectively (excluding the ground area of the original dwellinghouse and any hard surface or deck); or
(f) it would be within a conservation area.
4.37
Permitted development rights allow the erection,
construction or alteration of any porch outside any external door
of a dwellinghouse. The limitations are:
- the porch cannot have a footprint of greater than 3 square metres
- the minimum distance between the porch and any boundary and a road is more than 2 metres
- the height of the porch cannot be higher than 3 metres
4.38
If the porch exceeds any of the above limits then
an application
for planning permission
is required.
4.39
There are no permitted development rights for porches in a
conservation area
or for a flat. A
listed building consent
is required if the proposed extension affects the
character or setting of a
listed building
.
4.40
Planning authorities will be able to confirm whether a
property is located within a conservation area. Information on
listed buildings is available from
http://www.historic-scotland.gov.uk/historicandlistedbuildings
or
www.environment.scotland.gov.uk
4.41
A building warrant from the local authority may be required
for porches, as explained in
Section 2
.
LEGISLATION
Class 1C.-
(1) The erection, construction or alteration of any porch outside any external door of a dwellinghouse.
(2) Development is not permitted by this class if-
(a) its footprint would exceed 3 square metres;
(b) any part of it would be within 2 metres of a boundary between the curtilage of the dwellinghouse and a road;
(c) any part of the development would exceed 3 metres in height; or
(d) it would be within a conservation area.
SUMMARY
4.42
Permitted development rights allow the
enlargement
of a dwellinghouse by way of an addition or alteration to
its roof. This class typically relates to the addition of a dormer.
A badly designed dormer can harm the appearance of a dwellinghouse.
The larger the dormer, the more challenging it is to produce a good
design. In summary, the effect of the limitations is that:
- dormers are generally located to the rear
- the distance between the dormer and boundary it fronts is a minimum of 10 metres
- the height of the dormer is not higher than the existing dwellinghouse
- the dormer, or dormers, covers less than half the roof
- the distance between the dormer and the edge of the roof is a minimum of 0.3 metres
4.43
There are no permitted development rights to
enlarge a roof in a
conservation area
. Listed building consent will normally be required if
your building is Listed.
4.44
Building standards may apply and a building warrant from the
local authority may be required for this type of development as
explained in
Section 2
.
TECHNICAL EXPLANATION
4.45
If the development exceeds any of the following limits then
an
application for
planning permission
is required.
4.46
Figure 15 overleaf illustrates the restrictions for a
dormer, the highlighted areas indicate where the development is not
permitted as long as the other limitations are met.
4.47
There are no permitted development rights in a
conservation area
or for flats. A listed building consent is required if
the proposed development affects the character or setting of a
listed building.
4.48
Planning authorities will be able to confirm whether a
property is located within a
conservation area
. Information on listed buildings is available from
www.historic-scotland.gov.uk/historicandlistedbuildings
or
www.environment.scotland.gov.uk.
4.49
The development
cannot be part of the roof forming the principal
elevation or side elevation if that elevation is fronting a road.
The identification of the principal elevation and side elevations
are discussed in paragraphs
3.2 -
3.6, whilst
fronting a road
is discussed at
3.7 -
3.10.
4.50
Any enlargement or alteration to a roof is likely to have a
visual impact and potentially cause overlooking. The development
must be at least 10 metres from the boundary that it fronts.
4.51
The dormer must not exceed half the width of the roof plane
(the width of the roof plane is measured at the eaves line). The
development must be at least 0.3 metres from the edge of the roof
plane, for example the ridge of the roof or the edge of a hipped
roof.
4.52
The overall height of the dwellinghouse
cannot be increased as a result of the
development. This is measured against the existing ridge of the
roof.
Figure 15: Roof enlargements
LEGISLATION
Class 1D.-
(1) Any enlargement of a dwellinghouse by way of an addition or alteration to its roof.
(2) Development is not permitted by this class if-
(a) it would be on a roof plane forming part of the principal elevation or side elevation where that elevation fronts a road;
(b) it would be on a roof plane and would be within 10 metres of the boundary of the curtilage of the dwellinghouse which that roof plane fronts;
(c) as a result of the development the height of the dwellinghouse would exceed the height of the existing dwellinghouse, when measured at the highest part of the roof and excluding any chimney;
(d) its width would exceed half the total width of the roof plane, measured at the eaves line, of the dwellinghouse;
(e) any part of the development would be within 0.3 metres of any edge of the roof plane of the dwellinghouse; or
(f) it would be within a conservation area.
Introduction to improvements, additions or alterations to a dwellinghouse that are not an enlargement
4.53
There are many types of alterations or improvements to a
dwellinghouse
that are not
enlargement
. The most common types of alterations or improvements to
a dwellinghouses are described in classes 2A and 2B.
Access Ramps
Class 2A - The erection, construction or alteration of any access ramp outside any external door of a dwellinghouse.
This class allows small ramps to be attached to any external door of dwellinghouse so long as certain limitations are met. The ramp is not longer than 5 metres and the overall length of ramp and landings is not longer than 9 metres. The ramp is not higher than 0.4 metres and the combined height of the ramp and any handrail does not exceed 1.5 metres.
Improvements or alterations that are not an enlargement, including replacement windows, solar panels, flues and satellite dishes etc
Class 2B - Any improvement, addition or other alteration to the external appearance of a dwellinghouse that is not an enlargement.
This class is best visualised as a 1 metre bubble surrounding the walls and roof of a dwellinghouse. A householder can add a wide range of different types of development without having to apply for planning permission.
Wind turbines, balconies, raised terraces or platforms are not permitted by this class.
4.54
These permitted development rights do
NOT apply to
flats
.
4.55
If the proposed development falls into any of the above
classes and is in a
conservation area
then an application to the
planning
authority
is required.
Access Ramps
4.56
Permitted development rights allow the erection,
construction or alteration of any access ramp outside any external
door of a dwellinghouse. The limitations are:
- the length of all flights cannot be more than 5 metres
- the length of all flights and landings cannot be more than 9 metres
- the height of the access ramp, including associated handrails, cannot be higher than1.5 metres
- the height of the platform cannot be higher than 0.4 metres
4.57
If the access ramp exceeds any of the above limits, or is in
a
conservation area
, or within the curtilage of a listed building, then an
application for
planning permission
is required. Listed building consent is required if the
proposed access ramp affects the character or setting of a listed
building.
4.58
Scottish Building Standards require ramps to be safe.
Supporting guidance, including information on suitable gradients
and lengths of ramp, can be found in section 4.3 of the Scottish
Building Standards Technical Handbook available from
www.scotland.gov.uk/bsd.
4.59
Planning authorities will be able to confirm whether a
property is located within a conservation area. Information on
listed buildings is available from
www.historic-scotland.gov.uk/historicandlistedbuildings
or
www.environment.scotland.gov.uk.
4.60
When measuring the height of the development on sloping or
uneven ground, the height should be measured from the lowest point
immediately adjacent to the ramp.
LEGISLATION
Class 2A.-
(1) The erection, construction or alteration of any access ramp outside an external door of a dwellinghouse.
(2) Development is not permitted by this class if-
(a) the combined length of all flights forming part of the access ramp would exceed 5 metres;
(b) the combined length of all flights and landings forming part of the access ramp would exceed 9 metres;
(c) any part of the ramp would exceed 0.4 metres in height;
(d) the combined height of the ramp and any wall (excluding any external wall of the dwellinghouse), fence, balustrade, handrail or other structure attached to it would exceed 1.5 metres; or
(e) it would be within a conservation area or within the curtilage of a listed building.
Improvements or alterations that are not an enlargement, including replacement windows, solar panels, flues, and satellite dishes etc
4.61
Permitted development rights
allow any improvement, addition or other alteration to
the external appearance of a dwellinghouse that is not an
enlargement
. This is best visualised as a 1 metre bubble surrounding
the dwellinghouse. A householder can therefore carry out a wide
range of different types of development without having to apply for
planning permission. This class also covers the installation,
alteration or replacement of solar
PV or solar thermal equipment.
4.62
If the development exceeds any of the following limits then
an application for planning permission is required.
4.63
The development must not enlarge the dwellinghouse. This
means that the development cannot increase the internal volume of
the original building. This includes a canopy or roof, with or
without wall, which is attached to the building but does not
include a balcony.
4.64
The development must not project by more than 1 metre from
the wall or roof.
4.65
The following types of development are not permitted by this
class:
balcony, roof terrace or raised platform
wind turbine
4.66
The following developments are also not permitted as they
are permitted by other classes:
- access ramps
- a range of building or engineering operations including garden works, oil tanks
- a flue forming part of biomass heating system
- flue forming part of combined heat and power system
- air source heat pump
- CCTV
4.67
Section 6
discusses the installation, alteration or replacement of
a biomass heating system flue or a combined heat and powers system
flue or air source heat pump.
4.68
To ensure that the general character of an area is
maintained, there is a condition that materials used for any roof
covering must be similar in appearance to the existing roof. Solar
PV or solar thermal panels are not considered to
be a roof covering.
4.69
An alteration to the external appearance would allow the
painting (or repainting) of the property. It would also allow the
painting or attaching of an advertisement to the property. While an
application for planning consent may not be required by virtue of
this class, an application for advertisement consent may be
required under the Town and Country Planning (Control of
Advertisements) (Scotland) Regulations 1984 depending on the nature
and size of any such advertisement.
4.70
There are no Class 2B permitted development rights in a
conservation area
.
Listed building consent
is required if the proposed development affects the
character or setting of a
listed building
.
4.71
A building warrant from the local authority may be required,
as explained in
Section 2
.
4.72
Planning authorities will be able to confirm whether a
property is located within a conservation area. Information on
listed buildings is available from
http://www.historic-scotland.gov.uk/historicandlistedbuildings
or
www.environment.scotland.gov.uk.
LEGISLATION
Class 2B.-
(1)Any improvement, addition or other alteration to the external appearance of a dwellinghouse that is not an enlargement.
(2) Development is not permitted by this class if-
(a) it would protrude more than 1 metre from the outer surface of an external wall, roof plane, roof ridge or chimney of the dwellinghouse;
(b) it would be a wind turbine;
(c) it would be a balcony;
(d) it would be on the roof and would result in a raised platform or terrace;
(e) it would be within a conservation area; or
(f) it would be development described in class 2A(1), 3B(1), 6C(1), 6F(1), 6H(1) or 72(1).
(3) Development is permitted by this class subject to the condition that the materials used for any roof covering must be as similar in appearance to the existing roof covering as is reasonably practicable.
Introduction to other development within the curtilage of a dwellinghouse
4.73
There are many other types of developments that can happen
within the curtilage of dwellinghouse. The following 5 classes
cover the most common types of developments. Installation of
microgeneration equipment is discussed in
Section 6
.
Ancillary buildings including sheds, garages, sun-houses, greenhouses etc.
Class 3A - The provision within the curtilage of a dwellinghouse of any building required for a purpose incidental to the enjoyment of a dwellinghouse or the maintenance or improvement of such a building.
This class generally allows the provision of any building incidental to the enjoyment of the dwellinghouse if it is in the rear curtilage. In the main this covers sheds, garages, greenhouses etc.
In the case of dwellinghouses in a conservation area or within the curtilage of a listed building , the floor area of the ancillary building can not exceed 4 square metres.
Any building, engineering, installation or other operation
Class 3B - The carrying out of any building, engineering, installation or other operation within the curtilage of a dwellinghouse, required for a purpose incidental to the enjoyment of that dwellinghouse.
This class generally allows for the carrying out of an operation within the rear curtilage of a dwellinghouse not covered by other classes. Typical development permitted by this class include free-standing solar panels, flag poles, swimming pools, oil tanks etc.
This permitted development rights does not apply in conservation areas or within the curtilage of a listed building .
Hard surface
Class 3C - The provision within the curtilage of a dwellinghouse of a hard surface for any purpose incidental to the enjoyment of the dwellinghouse or the replacement in whole or in part of such a surface.
This class generally permits the construction or replacement of a hard surface. If the hard surface is between the dwellinghouse and a road then the materials used should be permeable or, alternatively, rain water run off should be to a permeable surface within the curtilage.
This permitted development rights for hard surfaces does not apply in conservation areas or within the curtilage of a listed building .
Decking or other raised platform
Class 3D - The erection, construction, maintenance, improvement or alteration of any deck or other raised platform within the curtilage of a dwellinghouse for any purpose incidental to the enjoyment of the dwellinghouse.
This class generally permits the construction of a deck or other raised platform in the rear garden so long as the floor level does not exceed 0.5 metres and the combined height of the deck and any attached balustrade or screening does not exceed 2.5 metres.
In the case of land in a conservation area or within the curtilage of a listed building , the footprint of the deck cannot exceed 4 square metres.
Gates, fences, walls or other means of enclosure
Class 3E - The erection, construction, maintenance, improvement or alteration of any gate, fence, wall or other means of enclosure any part of which would be within or would bound the curtilage of a dwellinghouse.
The overall height of the gate, fence, wall or other means of enclosure must not exceed 2 metres. However, if it fronts a road or comes forward of the principal elevation or side elevation nearest a road then it cannot exceed 1 metre. Where an existing gate, fence, wall or other means of enclosure is replaced or altered the height limit is either 1 metre or 2 metre or, if greater than these, the height of the original structure. These permitted development rights do not apply in a conservation area or within the curtilage of a listed building .
Ancillary buildings including sheds, garages, greenhouses etc
SUMMARY
4.74
Permitted development rights allow for the provision of any
building required for a purpose incidental to the enjoyment of the
dwellinghouse. Typical developments include sheds, garages,
sun-houses and greenhouses. In summary, the effect of the
limitations is that:
- ancillary buildings are generally located to the rear
- at least half the curtilage remains undeveloped
- the height of the building is not higher than 4 metres and the sections within 1 metre of the boundary would be higher than 2.5 metres
- the height of the eaves is not higher than 3 metres
4.75
In the case of dwellinghouses in a conservation area or
within the curtilage of a listed building development is permitted
development as long as the footprint of the ancillary building does
not exceed 4 square metres.
Listed building consent
is required if the proposed development affects the
character or setting of a
listed building
.
4.76
A building warrant from the local authority may be required
for these types of developments, as explained in
Section 2
.
TECHNICAL EXPLANATION
4.77
If the building exceeds any of the following limits then an
application for planning permission is required.
4.78
The building
cannot be used as a separate dwelling.
4.79
The building
cannot be forward of a wall forming part of the
principal elevation or side elevation if that elevation is fronting
a road. The identification of the
principal elevation
and side elevations are discussed in paragraphs 3.2 -
3.6, whilst
fronting a road
is discussed at 3.7 - 3.10.
4.80
This is illustrated below, the shaded areas of the curtilage
indicate where an ancillary building is permitted as long as the
other limitations are met.
4.81
The overall height of a building can have a significant
impact on neighbours. The
eaves
of the building
cannot be higher than 3 metres. The height of the
building
cannot exceed 4 metres.
4.82
The parts of the building within 1 metre of a boundary must
not be higher than 2.5 metres. This is illustrated on page 43.
4.83
When measuring the height of the development on sloping or
uneven ground, the height should be measured from the lowest point
immediately adjacent to the extension.
4.84
The proposed development and existing developments
(including extensions, sheds, garages) cannot exceed half of the of
the rear (or front if appropriate) curtilage of the original
dwellinghouse, this is explained in paragraphs 3.11 - 3.12.
4.85
In the case of dwellinghouses in a
conservation area
or within the curtilage of a
listed building
, the floor area of the ancillary building cannot exceed 4
square metres. A
listed building consent
is required if the proposed development affects the
character or setting of a
listed building
.
4.86
Planning authorities will be able to confirm whether a
property is located within a conservation area. Information on
listed buildings is available from
www.historic-scotland.gov.uk/historicandlistedbuildings
or
www.environment.scotland.gov.uk.
LEGISLATION
Class 3A.-
(1) The provision within the curtilage of a dwellinghouse of a building for any purpose incidental to the enjoyment of that dwellinghouse or the alteration, maintenance or improvement of such a building.
(2) Development is not permitted by this class if-
(a) it consists of a dwelling;
(b) any part of the development would be forward of a wall forming part of the principal elevation or side elevation where that elevation fronts a road;
(c) the height of the eaves would exceed 3 metres;
(d) any part of the development would exceed 4 metres in height;
(e) any part of the development within 1 metre of the boundary of the curtilage of the dwellinghouse would exceed 2.5 metres in height;
(f) as a result of the development the area of ground covered by development within the front or rear curtilage of the dwellinghouse (excluding the original dwellinghouse and any hard surface or deck) would exceed 50% of the area of the front or rear curtilage respectively (excluding the ground area of the original dwellinghouse and any hard surface or deck); or
(g) in the case of land in a conservation area or within the curtilage of a listed building, the resulting building would have a footprint exceeding 4 square metres.
Any building, engineering, installation or other operation
SUMMARY
4.87
Permitted development rights allow for the carrying out of
works within the rear curtilage of a dwellinghouse not covered by
other classes. It is intended to apply to garden works,
free-standing solar panels, flag poles, swimming pools and oil
tanks. In summary, the effect of limitations is that:
- the development is generally located in the rear
- the height of the resulting structure is not higher than 3 metres
- at least half the curtilage remains undeveloped
4.88
This permitted development rights do not apply in
conservation areas
or within the curtilage of a
listed building
.
4.89
A building warrant from the local authority may be required
for these types of developments, as explained in
Section 2
.
TECHNICAL
4.90
If the development exceeds any of the following limits then
an application for planning permission is required.
4.91
Building operation is included in the description, as in
terms of the definition of development and includes a wider range
of development than just the provision of an actual building.
4.92
The development
cannot be forward of a wall forming part of the
principal elevation or side elevation if that elevation is fronting
a road. The identification of the
principal elevation
and side elevations are discussed in paragraphs
3.2 -
3.6, whilst
fronting a road
is discussed at
3.7 -
3.10.
4.93
This is illustrated below, the shaded areas of the curtilage
indicate where works is permitted as long as the other limitations
are met.
4.94
The overall height of the development can have a significant
impact on neighbours. The development
cannot be higher than 3 metres. When measuring the
height of the development on sloping or uneven ground, the height
should be measured from the lowest point immediately adjacent to
the development.
4.95
The proposed development and existing developments
(including extensions, sheds, garages
etc.)
cannot exceed half of the rear curtilage (or front
if appropriate) curtilage of the original dwellinghouse, this is
explained in paragraphs
3.12 -
3.13.
4.96
The following types of development are not permitted by this
class, as these types of developments are permitted by other
classes:
- ancillary buildings
- hard surface
- decking
- gate, fence, wall or other means of enclosure
- ground source heat pump
- water source heatpump
- free-standing wind turbine
- air source heat pump
- means of access
4.97
There are no Class 3B permitted development rights in a
conservation area
or within the curtilage of a
listed building
. An application to the planning authority is
required.
4.98
Planning authorities will be able to confirm whether a
property is located within a
conservation area
. Information on
listed buildings
is available from
www.historic-scotland.gov.uk/historicandlistedbuildings
or
www.environment.scotland.gov.uk.
LEGISLATION
Class 3B.-
(1) The carrying out of any building, engineering, installation or other operation within the curtilage of a dwellinghouse for any purpose incidental to the enjoyment of that dwellinghouse.
(2) Development is not permitted by this class if-
(a) any part of the development would be forward of a wall forming part of the principal elevation or side elevation where that elevation fronts a road;
(b) any resulting structure would exceed 3 metres in height;
(c) as a result of the development the area of ground covered by development within the front or rear curtilage of the dwellinghouse (excluding the original dwellinghouse and any hard surface or deck) would exceed 50% of the area of the front or rear curtilage respectively (excluding the ground area of the original dwellinghouse and any hard surface or deck);
(d) it would be within a conservation area or within the curtilage of a listed building; or
(e) it would be development described in class 3A(1), 3C(1), 3D(1), 3E(1), 6D, 6E, 6G(1), 6H(1) or 8.
Hard surface
4.99
Permitted development rights allow the construction or
replacement of a hard surface within the curtilage of a
dwellinghouse.
4.100
If the hard surface exceeds any of the following limits then
an application for planning permission is required.
4.101
If the hard surface is located between the dwellinghouse and
a road, then it must be constructed of a porous material or that
provision is made for surface water run off to be directed to a
porous area within the curtilage of the dwellinghouse.
4.102
This provision is introduced following a review of extreme
flooding events and concerns expressed by regulatory authorities
and water companies that the cumulative impact of small increases
in hard surfacing is leading to increased run off into road drains
that ultimately flow into watercourses or sewage treatment works.
The intention of the condition is to encourage householders to
adopt the principles of source control.
4.103
The Department of Communities and Local Government has
produced separate guidance on permeable paving. This can be found
at:
www.communities.gov.uk/documents/planningandbuilding/pdf/pavingfrontgardens.pdf.
4.104
Planning permission is required for a hard surface in
conservation areas
and in the curtilage of
listed buildings
. A building warrant from the local authority may be
required, as explained in
Section 2
.
4.105
Planning authorities will be able to confirm whether a
property is located within a
conservation area
. Information on
listed buildings
is available from:
www.historic-scotland.gov.uk/historicandlistedbuildings
or
www.environment.scotland.gov.uk.
LEGISLATION
Class 3C.-
(1) The provision within the curtilage of a dwellinghouse of a hard surface for any purpose incidental to the enjoyment of that dwellinghouse or the replacement in whole or in part of such a surface.
(2) Development is not permitted by this class if it would be within a conservation area or within the curtilage of a listed building.
(3) Development is permitted by this class subject to the condition that where the hard surface would be located between the dwellinghouse and a road bounding the curtilage of the dwellinghouse-
(a) the hard surface must be made of porous materials; or
(b) provision must be made to direct run off water from the hard surface to a permeable or porous area or surface within the curtilage of the dwellinghouse.
Decking or other raised platform
SUMMARY
4.106
Permitted development rights allow the erection,
construction, maintenance, improvement or alteration of any deck or
other raised platform within the curtilage of a dwellinghouse. In
summary, the effect of the limitations is that:
- decks are generally located to the rear
- the height of the floor level does not exceed 0.5 metre
- the total height of the deck, including any attached structure does not exceed 2.5 metres
4.107
If the deck, or raised platform, is in a conservation area
or within the curtilage of listed building the maximum size of the
deck, or raised platform, is 4 square metres. There are no
permitted development rights for flats.
4.108
A building warrant from the local authority may be required
for the deck or other raised platform, as explained in
Section 2
.
TECHNICAL EXPLANATION
4.109
If the deck, or raised platform, exceeds any of the
following limits then
an application
for planning permission
is required.
4.110
Decks cannot be forward of a wall forming part of the
principal elevation or side elevation if that elevation is fronting
a road. The identification of the
principal elevation
and side elevations are discussed in paragraphs
3.2 -
3.6, whilst
fronting a road
is discussed at
3.7 -
3.10.
4.111
This is illustrated below, the shaded areas of the curtilage
indicate where an extension is permitted as long as the other
limitations are met.
4.112
The maximum height of the platform of the decking is 0.5
metre. The total height if, for example screens are attached, is
2.5 metres.
4.113
When measuring the height of the deck on sloping or uneven
ground, the height should be measured from the lowest point
immediately adjacent to the decking.
4.114
The size of decking in
conservation areas
and within the curtilage of
listed buildings
is restricted to 4 square metres to be permitted
development.
4.115
Planning authorities will be able to confirm whether a
property is located within a
conservation area
. Information on
l
isted buildings is available from
www.historic-scotland.gov.uk/historicandlistedbuildings
or
www.environment.scotland.gov.uk.
LEGISLATION
Class 3D.-
(1) The erection, construction, maintenance, improvement or alteration of any deck or other raised platform within the curtilage of a dwellinghouse for any purpose incidental to the enjoyment of that dwellinghouse.
(2) Development is not permitted by this class if-
(a) any part of the development would be forward of a wall forming part of the principal elevation or side elevation where that elevation fronts a road;
(b) the floor level of any part of the deck or platform would exceed 0.5 metres in height;
(c) the combined height of the deck and any wall, fence, balustrade, handrail or other structure attached to it, would exceed 2.5 metres; or
(d) in the case of land within a conservation area or within the curtilage of a listed building the deck or platform would have a footprint exceeding 4 square metres.
Gates, fences, walls or other means of enclosure
4.116
Permitted development rights allow the erection,
construction, maintenance, improvement or alteration of any gate,
fence, wall or other means of enclosure.
4.117
If the gate, fence, wall or other means of enclose exceeds
the following limits then an application for planning permission is
required.
4.118
The maximum height of any gate, fence, wall or other means
of enclosure is 2 metres. Whilst its maximum height 1 metre if it
fronts a road (explained in paragraphs 3.9 - 3.10) or comes forward
of the
principal elevation
or side elevation nearest a road. Identifying the
principal elevation is explained in paragraphs 3.2 - 3.6.
4.119
When measuring the height of the development on sloping or
uneven ground, the height should be measured from the lowest point
immediately adjacent to the gate, fence, wall or other means of
enclosure.
4.120
The replacement or alteration of an existing gate, fence,
wall or other means of enclosure to its original height is
permitted. For example, an existing 1.2 metre fence forward of the
principal elevation can be replaced with a fence up to 1.2 metres
in height. If the replacement fence is higher than 1.2 metres then
an application for planning permission would be required.
Alternatively, if replacing a 0.8 metre high fence forward of the
principal elevation
it can be replaced by with a fence up to 1 metre in
height.
4.121
Planning permission is needed for gates, fences, wall or
other mean of enclosure in
conservation areas
and in the curtilage of
listed buildings
.
4.122
Planning authorities will be able to confirm whether a
property is located within a
conservation area
. Information on
listed buildings
is available from
www.historic-scotland.gov.uk/historicandlistedbuildings
or
www.environment.scotland.gov.uk.
LEGISLATION
Class 3E.-
(1) The erection, construction, maintenance, improvement or alteration of any gate, fence, wall or other means of enclosure any part of which would be within or would bound the curtilage of a dwellinghouse.
(2) Development is not permitted by this class if-
(a) any part of the resulting gate, fence, wall or other means of enclosure would exceed 2 metres in height;
(b) any part of the resulting gate, fence, wall or other means of enclosure would exceed one metre in height where it-
(i) fronts a road; or
(ii) extends beyond the line of the wall of the principal elevation or side elevation that is nearest a road;
(c) it replaces or alters an existing gate, fence, wall or other means of enclosure and exceeds whichever is the greater of the original height or the heights described in sub-paragraphs (a) and (b);
(d) it would be within a conservation area; or
(e) it would be within, or bound, the curtilage of a listed building.
Contact
Central enquiry unit: ceu@gov.scot
There is a problem
Thanks for your feedback